Shimadzu SPD-10A UV-VIS Detector
sku86741 — low stock
10% Store Wide!Save $120.00
$1,080.00CAD$1,200.00
By Shimadzu
<p>Shimadzu SPD-10A UV-VIS Detector </p><p>    Light source: Deuterium lamp     Wavelength range:         190 ~ 600 nm         Cut filter for second order diffracting light is automatically inserted i…
Description
<p>Shimadzu SPD-10A UV-VIS Detector </p><p>    Light source: Deuterium lamp
    Wavelength range:
        190 ~ 600 nm
        Cut filter for second order diffracting light is automatically inserted in the 371- 600nm range
    Spectral bandwidth: 8 nm
    Wavelength accuracy: ± 1 nm
    Wavelength reproducibility: ± 0.1 nm
    Cell path length: 10nm
    Cell volume: 8ul
    Cell pressure tolerance: 12MPa
    Dual wavelength mode:
        Measuring wavelength: Aritrary two wavelengths in 190- 370 nm or 371-600 nm
        Sampling period: 1.2 sec for one wavelength
    Response: Selectable in 9 steps corresponding to time constant 0.05, 0.1, 0.5, 1.0, 1.5, 3.0, 6.0, 8.0, 10.0   
    seconds
    Range: Can be set between 0.0001 and 2.56 AUFS in 0.0001 AUFS steps
    Zero adjustment: Auto zero function, baseline shift function
    Wavelength scanning function: Performs wavelength scanning with flow stopped. Data stored in three files, one of 
    which stores background. Background is subtracted from sample scans. File data is not saved up (lost when
    power is turned OFF).
    Time Program: Available in detector or by system controller
        Set items: Wavelength ( including dual wavelengths), auto zero, range, marker, response, wavelength scanning,
    event, polarity, lamp ON/OFF, loop
        Number of steps: Maximum 32 steps
    Output
        Output for Recorder: 1 mv, 10 mV, maximum output voltage is approx. 20 times as much as full scale
        Output for Integrator: 0.5, 1, 2, 4, AU/V in 4 steps
 </p><p>*Cables included</p>
    Wavelength range:
        190 ~ 600 nm
        Cut filter for second order diffracting light is automatically inserted in the 371- 600nm range
    Spectral bandwidth: 8 nm
    Wavelength accuracy: ± 1 nm
    Wavelength reproducibility: ± 0.1 nm
    Cell path length: 10nm
    Cell volume: 8ul
    Cell pressure tolerance: 12MPa
    Dual wavelength mode:
        Measuring wavelength: Aritrary two wavelengths in 190- 370 nm or 371-600 nm
        Sampling period: 1.2 sec for one wavelength
    Response: Selectable in 9 steps corresponding to time constant 0.05, 0.1, 0.5, 1.0, 1.5, 3.0, 6.0, 8.0, 10.0   
    seconds
    Range: Can be set between 0.0001 and 2.56 AUFS in 0.0001 AUFS steps
    Zero adjustment: Auto zero function, baseline shift function
    Wavelength scanning function: Performs wavelength scanning with flow stopped. Data stored in three files, one of 
    which stores background. Background is subtracted from sample scans. File data is not saved up (lost when
    power is turned OFF).
    Time Program: Available in detector or by system controller
        Set items: Wavelength ( including dual wavelengths), auto zero, range, marker, response, wavelength scanning,
    event, polarity, lamp ON/OFF, loop
        Number of steps: Maximum 32 steps
    Output
        Output for Recorder: 1 mv, 10 mV, maximum output voltage is approx. 20 times as much as full scale
        Output for Integrator: 0.5, 1, 2, 4, AU/V in 4 steps
 </p><p>*Cables included</p>