<p>Shimadzu SPD-10A UV-VIS Detector </p><p>&#160;&#160;&#160; Light source: Deuterium lamp &#160;&#160;&#160; Wavelength range: &#160;&#160;&#160;&#160;&#160;&#160;&#160; 190 ~ 600 nm &#160;&#160;&#160;&#160;&#160;&#160;&#160; Cut filter for second order diffracting light is automatically inserted i…

Description
<p>Shimadzu SPD-10A UV-VIS Detector </p><p>&#160;&#160;&#160; Light source: Deuterium lamp
&#160;&#160;&#160; Wavelength range:
&#160;&#160;&#160;&#160;&#160;&#160;&#160; 190 ~ 600 nm
&#160;&#160;&#160;&#160;&#160;&#160;&#160; Cut filter for second order diffracting light is automatically inserted in the 371- 600nm range
&#160;&#160;&#160; Spectral bandwidth: 8 nm
&#160;&#160;&#160; Wavelength accuracy: ± 1 nm
&#160;&#160;&#160; Wavelength reproducibility: ± 0.1 nm
&#160;&#160;&#160; Cell path length: 10nm
&#160;&#160;&#160; Cell volume: 8ul
&#160;&#160;&#160; Cell pressure tolerance: 12MPa
&#160;&#160;&#160; Dual wavelength mode:
&#160;&#160;&#160;&#160;&#160;&#160;&#160; Measuring wavelength: Aritrary two wavelengths in 190- 370 nm or 371-600 nm
&#160;&#160;&#160;&#160;&#160;&#160;&#160; Sampling period: 1.2 sec for one wavelength
&#160;&#160;&#160; Response: Selectable in 9 steps corresponding to time constant 0.05, 0.1, 0.5, 1.0, 1.5, 3.0, 6.0, 8.0, 10.0&#160;&#160;&#160;
&#160;&#160;&#160; seconds
&#160;&#160;&#160; Range: Can be set between 0.0001 and 2.56 AUFS in 0.0001 AUFS steps
&#160;&#160;&#160; Zero adjustment: Auto zero function, baseline shift function
&#160;&#160;&#160; Wavelength scanning function: Performs wavelength scanning with flow stopped. Data stored in three files, one of&#160;
&#160;&#160;&#160; which stores background. Background is subtracted from sample scans. File data is not saved up (lost when
&#160;&#160;&#160; power is turned OFF).
&#160;&#160;&#160; Time Program: Available in detector or by system controller
&#160;&#160;&#160;&#160;&#160;&#160;&#160; Set items: Wavelength ( including dual wavelengths), auto zero, range, marker, response, wavelength scanning,
&#160;&#160;&#160; event, polarity, lamp ON/OFF, loop
&#160;&#160;&#160;&#160;&#160;&#160;&#160; Number of steps: Maximum 32 steps
&#160;&#160;&#160; Output
&#160;&#160;&#160;&#160;&#160;&#160;&#160; Output for Recorder: 1 mv, 10 mV, maximum output voltage is approx. 20 times as much as full scale
&#160;&#160;&#160;&#160;&#160;&#160;&#160; Output for Integrator: 0.5, 1, 2, 4, AU/V in 4 steps
&#160;</p><p>*Cables included</p>