<p>DC 3-Wire Model , Shielded , M5 , Sensing Distance 1 mm , Operation Mode NO , NPN  </p><ul><li>Cylinder type sensing head size     M5</li><li>Type     Shielded</li><li>Sensing method     Inductive type</li><li>Sensing distance     1…
Description
<p>DC 3-Wire Model , Shielded , M5 , Sensing Distance 1 mm , Operation Mode NO , NPN
 </p><ul><li>Cylinder type sensing head size     M5</li><li>Type     Shielded</li><li>Sensing method     Inductive type</li><li>Sensing distance     1 mm -15% to +15%</li><li>Setting distance     0 to 0.7 mm</li><li>Differential distance     15% Max. of sensing distance</li><li>Sensing object     Ferrous metal (Sensitivity lowers with non-ferrous metals.)</li><li>Standard sensing object     Iron 5*5*1mm</li><li>Response frequency     DC: 3 kHz (average)</li><li>Power supply voltage     12 to 24 VDC (ripple(p-p) :10% Max.)</li><li>Operating voltage range     10 to 30 VDC</li><li>Current consumption     17 mA Max.</li><li>Control output (Output type)     NPN open collector output</li><li>Control output (Switching capacity)     0 to 100 mA (30VDC Max.)</li><li>Control output (Residual voltage)     (DC) 2 V Max. (under load current with cable length of 2m)</li><li>Indicator     Operation indicator(red)</li><li>Operation mode     NO</li><li>Protective circuit     Surge suppressor</li><li>Power supply reverse polarity protection</li><li>Standard or Different frequency     Standard</li><li>Ambient temperature     Operating: -25 to 70 CEL</li><li>Storage: -25 to 70 CEL</li><li>(with no icing or condensation)</li><li>Ambient humidity     Operating: 35 to 95 %RH</li><li>Storage: 35 to 95 %RH</li><li>(with no condensation)</li><li>Temperature influence     +-15% Max. of sensing distance in temperature range of -25 to +70CEL</li><li>(As the basis for sensing distance of 23CEL)</li><li>Voltage influence     +-2.5% Max. of sensing distance in rated voltage range +-15%. (As the basis for sensing distance at standard power voltage)</li><li>Insulation resistance     50 M OHM Min. at 500VDC between charged parts and the case</li><li>Dielectric strength     500 VAC 50/60 Hz for 1 minute between charged parts and the case</li><li>Vibration resistance     10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions</li><li>Shock resistance     500m/s2 for 10 times each in X, Y, and Z directions</li><li>Degree of protection     IEC60529: IP67</li><li>Company standard: Oil-proof</li></ul>
 </p><ul><li>Cylinder type sensing head size     M5</li><li>Type     Shielded</li><li>Sensing method     Inductive type</li><li>Sensing distance     1 mm -15% to +15%</li><li>Setting distance     0 to 0.7 mm</li><li>Differential distance     15% Max. of sensing distance</li><li>Sensing object     Ferrous metal (Sensitivity lowers with non-ferrous metals.)</li><li>Standard sensing object     Iron 5*5*1mm</li><li>Response frequency     DC: 3 kHz (average)</li><li>Power supply voltage     12 to 24 VDC (ripple(p-p) :10% Max.)</li><li>Operating voltage range     10 to 30 VDC</li><li>Current consumption     17 mA Max.</li><li>Control output (Output type)     NPN open collector output</li><li>Control output (Switching capacity)     0 to 100 mA (30VDC Max.)</li><li>Control output (Residual voltage)     (DC) 2 V Max. (under load current with cable length of 2m)</li><li>Indicator     Operation indicator(red)</li><li>Operation mode     NO</li><li>Protective circuit     Surge suppressor</li><li>Power supply reverse polarity protection</li><li>Standard or Different frequency     Standard</li><li>Ambient temperature     Operating: -25 to 70 CEL</li><li>Storage: -25 to 70 CEL</li><li>(with no icing or condensation)</li><li>Ambient humidity     Operating: 35 to 95 %RH</li><li>Storage: 35 to 95 %RH</li><li>(with no condensation)</li><li>Temperature influence     +-15% Max. of sensing distance in temperature range of -25 to +70CEL</li><li>(As the basis for sensing distance of 23CEL)</li><li>Voltage influence     +-2.5% Max. of sensing distance in rated voltage range +-15%. (As the basis for sensing distance at standard power voltage)</li><li>Insulation resistance     50 M OHM Min. at 500VDC between charged parts and the case</li><li>Dielectric strength     500 VAC 50/60 Hz for 1 minute between charged parts and the case</li><li>Vibration resistance     10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions</li><li>Shock resistance     500m/s2 for 10 times each in X, Y, and Z directions</li><li>Degree of protection     IEC60529: IP67</li><li>Company standard: Oil-proof</li></ul>